LIC 4117 / LIC 4197

    Specifications

    Linear scale

    LIC 4007

    Measuring standard

    Coefficient of linear expansion

    Steel scale tape with METALLUR absolute and incremental track

    αtherm  10 · 10–6 K–1

    Accuracy grade*

    ±3 µm (up to ML 1040), ±5 µm (starting from ML 1240), ±15 µm1)

    Baseline error

    ±0.750 µm/50 mm (typical)

    Measuring length ML* in mm

    240 440 640 840 1040 1240 1440 1640 1840 2040 2240 2440 2640 2840

    3040 3240 3440 3640 3840 4040 4240 4440 4640 4840 5040 5240 5440 5640

    5840 6040

    Mass Scale tape

    Parts kit

    Scale-tape carrier

    31 g/m

    20 g

    68 g/m

    Scanning head

    AK LIC 411

    AK LIC 419 F

    AK LIC 419 M

    AK LIC 419 P

    Interface

    EnDat 2.2

    Fanuc Serial Interface

    αi interface

    Mitsubishi high speed interface

    Panasonic
    Serial Interface

    Ordering designation*

    EnDat22

    Fanuc05

    Mit03-4

    Mit02-2

    Pana01

    Measuring step*

    0.01 µm (10 nm)

    0.005 µm (5 nm)

    0.001 µm (1 nm)

    0.01 µm (10 nm)

    0.005 µm (5 nm)

    0.001 µm (1 nm)3)

    0.01 µm (10 nm)

    0.005 µm (5 nm)

    0.001 µm (1 nm)

    Calculation time tcal

    Clock frequency

    5 µs

    16 MHz

    Traversing speed2)

    600 m/min

    Interpolation error

    ±20 nm

    Electrical connection*

    Cable, 1 m or 3 m with 8-pin M12 coupling (male) or 15-pin D-sub connector (male)

    Cable length
    (with HEIDENHAIN cable)

    100 m

    50 m

    30 m

    50 m

    Voltage supply

    DC 3.6 V to 14 V

    Power consumption2) (max.)

    At 3.6 V: 800 mW

    At 14 V: 900 mW

    At 3.6 V: 950 mW

    At 14 V: 1050 mW

    Current consumption (typical)

    At 5 V: 75 mA (without load)

    At 5 V: 95 mA (without load)

    Vibration 55 Hz to 2000 Hz

    Shock 6 ms

    500 m/s2 (EN 60 068-2-6)

    1000 m/s2 (EN 60 068-2-27)

    Operating temperature

    –10 °C to 70 °C

    Mass Scanning head

    Connecting cable

    Connector

    18 g (without cable)

    20 g/m

    M12 coupling: 15 g; D-sub connector: 32 g

    * Please select when ordering

    1) ±5 µm after linear length-error compensation in the evaluation electronics

    2) See General electrical information in the brochure Interfaces for HEIDENHAIN Encoders

    3) Up to measuring length ML 4140