Menü überspringen

IDP 100 Series

Request

Documentation

undefinedProduct Information

General specifications

IDP 101

IDP 181

IDP 182

Power supply

5 V ± 5%

Current consumption1)

≤ 100 mA

≤ 120 mA

≤ 130 mA

Cable length

Input


≤ 30 m at IEncoder 120 mA


≤ 30 m at IEncoder 120 mA
≤ 60 m at UP > 4.9 V

Output

≤ 50 m with HEIDENHAIN cable and differential line receiver at the subsequent electronics input

Vibration 55 to 2000 Hz

Shock 6 ms

20 m/s2

300 m/s2

Operating temperature

Storage temperature

0 to 70 °C

–30 to 80 °C

Protection IEC 60529

IP 00

Weight

Approx. 0.1 kg

Caution:

The permitted limits for the power supply of the connected encoder must not be exceeded.

1)Without current consumption by the encoder and without output load:
Subsequent electronics with the recommended input circuitry increase current consumption by approx. 80 mA